Products

DMMS [Digital Moisture Measuring System]




Overview

Based on long­term practical experiences the moisture measuring sensors are made for the toughest operations and industrial applications. DMMS is especially suitable for challenging applications. Up to 16 sensors are able to communicate digitally with a central evaluation unit. Wiring becomes easy by using bus­technology. That makes it simple to upgrade the measuring points. The bus­system can manage a max. length of 1.200 meter which allows you to cover even spacious estates. The calibration is made on­line within the process, so after the sensor has already been installed.


DMMS Sensor

As a result the influences caused by the assembly situation can be immediately detected and compensated. The kind of measurement can be chosen for each sensor between continuous and batch operation (via start and stop signal). It's also possible to switch the material curves for each sensor (up to 16 different material curves per sensor). The transfer of the measuring values can be done digitally by Profibus DP or by analogue output (e.g. 4...20mA, 0...10V). If the sensor has to be replaced the calibration curves can be completely adopted ­ there's no additional effort. In almost every kind of bulk material a precise determination of the moisture can be done, e.g. sand, minerals, clay, grain, food stuff, saw dust, ores, sewage sludge and so on.




Technical Details - DMMS Sensor

Physical measuring principle Capacitive (determination with high­frequency leakage field, 16...22 MHz)
Measuring range  Moisture: 0...100 %, Temperature: ­ 20...120 °C (both ranges adjustable)
Accuracy       +/­ 0,1 % moisture (depending on material/sensor installation place)
Mode     Continuous or batch measuring
Ambient / material temperature 4...80 °C
Temperature compensation of sensor electronic and material
Measuring depth  ca. 150 mm (depending on material/compaction)
Sensor dimensions  Ø = 76 mm / H = 70 mm
Materials housing / wear protection  Stainless steel (1.4301), ceramic (ZrO2Al2O3)
Protection class  IP68
Sensor mounting Clamp flange (variable installation depth)
Power supply 24 V DC / 0,4 VA (per sensor)
Sensor cable LiYD11Y 6 x 0.14 mm2, shielded, 6m long
 
DIGISYS evaluation unit
Output Profibus DP or optional analogue standard signal (e.g. 4...20 mA)
max. number of sensors    16
Sensor communication Sensor bus RS485
max. cable length  400 m, resp. 1.200 m
Bus cable  2 x 2 x 0,25 mm 2 ,shielded twisted pair cable
Bus­ connection­ box   IP66, aluminum housing (voltage supply, bus­ connection and addressing for up to 2 sensors)
Requirements for calibration software WIN 95 / 98 / ME / 2000 / XP / Vista / 7 / 8 / 10+ USB, RS232 or LAN connection
Versions / Options  Certification for explosion­risk area, ex zone 22 (II 3D Ex tD A22 IP6X T85°C)
Sensor with extended temperature range, up to 100°C
Sensor for measurement in silo
Sensor for measurement mixer
Sensor housing made of acid proof stainless steel (1.4462)
Digital inputs and outputs







MMS [Universal moisture sensor]




Overview

The moisture measuring sensors are made for the toughest operations and industrial applications. The sensors are constructed based on long-terms practical experiences for permanent use. Without much effort it can be installed – also afterwards – into the process.


MMS Sensor

The moisture measuring sensors are made for the toughest operations and industrial applications. The sensors are constructed based on long-terms practical experiences for permanent use. Without much effort it can be installed – also afterwards – into the process.







Technical Details - DMMS Sensor

Physical measuring principial capacitive (determination with high-frequency leakage field 27 MHz)
Measuring range Moisture: 0…100 % (adjustable)
Accuracy       +/­ 0,1 % moisture (depending on material/sensor installation place)
Mode     Continuous or batch measuring
Ambient / material temperature 4...80 °C
Temperature compensation of sensor electronic and material
Measuring depth  ca. 150 mm (depending on material/compaction)
Sensor dimensions  Ø = 76 mm / H = 70 mm
Materials housing / wear protection  Stainless steel (1.4301), ceramic (ZrO2Al2O3)
Protection class  IP68
Sensor mounting Clamp flange (variable installation depth)
Power supply 24 V DC / 0,4 VA (per sensor)
Sensor cable LiYD11Y 6 x 0.14 mm2, shielded, 6m long
 
DIGISYS evaluation unit
Output Profibus DP or optional analogue standard signal (e.g. 4...20 mA)
max. number of sensors    16
Sensor communication Sensor bus RS485
max. cable length  400 m, resp. 1.200 m
Bus cable  2 x 2 x 0,25 mm 2 ,shielded twisted pair cable
Bus­ connection­ box   IP66, aluminum housing (voltage supply, bus­ connection and addressing for up to 2 sensors)
Requirements for calibration software WIN 95 / 98 / ME / 2000 / XP / Vista / 7 / 8 / 10+ USB, RS232 or LAN connection
Versions / Options  Certification for explosion­risk area, ex zone 22 (II 3D Ex tD A22 IP6X T85°C)
Sensor with extended temperature range, up to 100°C
Sensor for measurement in silo
Sensor for measurement mixer
Sensor housing made of acid proof stainless steel (1.4462)
Digital inputs and outputs